Category

Your position: Home Products Angle Sensor Electrolytic LE-60-F

Product:LE-60-F
Download: No file to download

Introduce:
1.      Product Feature
         Digital Roll and Pitch Output                     
         RS-232 Interface                                   
         Programmable Resolution and Settling Time
2.      Product Applications
         Platform Leveling
         Precision Tilt Measurements
         Geo-mechanical Leveling
         Lab Instrumentation
3.       Specifications
Specifications
      LE-60-F
Remarks
Performance
 Accuracy (°)
       ± 0.1
at ± 20° (at 25°C)
 Angular Range (°)
       ± 75
From horizontal
 Angular Drift w/Temp (°)
       0.7
Up to ± 20° Tilt
 Angular Resolution (°)
      See Table 1
 
 Null Angular Offset (°)
      < 0.5
Actual value provided w/sensor
 Non-Linearity (± 45°) (%)
      < 0.3
Measured at 25O C
 Transverse Sensitivity (%)
        1
Typical
Environment
Temperature Range (°C)
-40 to +85
 
Electrical
 RS-232 Interface (Baud)
       9600
 
 Supply Voltage (Volts DC)
       8-30
 
 Supply Current (mA)
        60
 
Physical
Size
4.02 x 2.26 x 1.24” (10.21 x 5.74 x 3.15 cm)
   Weight
    2.9 oz (90 gm) 
 
   Cable Length (feet)
      2.5
 
       
     Specifications subject to change without notice
 
                                                                     Table 1
    Filter
    Fc(Hz)
     Tc(s)
Typical Resolution (o)
     0
none
none
0.320
1
12.5
0.025
0.101
2
9.9
0.029
0.091
3
5.0
0.042
0.064
4
2.5
0.074
0.045
5
1.2
0.14
0.032
     6
0.64
0.26
0.023
7
0.33
0.52
0.016
8
0.17
1.03
0.012
9
0.09
2.05
0.009
       Note:
       Filter 0 implies no digital IIR filter, but there is a 125 Hz ± 35 Hz single pole response
       from the MEMS sensor
 
4.    Application Information
Command
Function Description/Response
R
Reset. Resets the LE-60-F firmware to default settings.
An ASCII ‘H’ (72) is sent in response.
 
G
Get Angle Data Packet. The LE-60-F returns its current angular position. The data is in a 6 byte packet defined in Table 2
 
N<0-9>
Set Resolution Level. A 2 byte command sequence that configures the LE-60-F internal digital filter. The second byte, an integer of value 0-9, sets the level of filtering.
C
Continuous Mode: Transfers packet continuously at maximum rate.
S
Stop Continuous Mode
 
                                                                      Table 2
Contents of Data Packet
Byte
Description
Note: Angles are represented as two’s
complement 16 bit numbers. +90° corresponds to 32,767. -90°corresponds to -32,768. The 16-bit signed angle can be obtained by this simple ‘C’ expression: (int) Roll LSB + (int) 256 * Roll MSB
0
Header (always 255)
1
Pitch MSB (0-255)
2
Pitch LSB (0-255)
3
Roll MSB (0-255)
4
Roll LSB (0-255)
5
Checksum (8-bit sum of bytes 1-4)
 
5.   Pin Diagram
        Pin
    Function
        4
Transmit Data
        3
Receive Data
        1
GND
        11
Input Power

Copyright: Xi'an Rapid Nav M&C Co.,Ltd
Phone :86-29-82501710 Fax:86-29-82501710 / E-mail: admin@navmc.com
Address: 169 Golden Flower North Road, Xi'an / Zip code: 710032